- cavePools.deepFluid fills pools at or below cavePools.deepFluidMaxY, default world Y -128, unset by default
- A cave policy fluid still wins over the deep fluid
- The mixed-fluid check stops a pool rising past the line, so no pool straddles it
- CavePoolFiller takes the world minimum Y to place the line, and throws when the line is outside the world
- Settings reject an unknown or seam deepFluid, and both knobs join the fingerprint
- Default fingerprint and schema digest recaptured
- Keep a horseshoe tip off the outlet zone end and reach start
- Scan segments upstream of a fall for horseshoe water in settlement
- Measure the brink cap from the real brink and pin it at 11
- Replace the angled 1.25 bound with rule and square-on checks
- Add behaviour tests for every ReachGeometry guard and use site
- Add ReachGeometry and the shared curved brink head rule
- Use it in RasterComposer and PondChannelSettlement
- Add T8, T9 and multi-seed brink tests
- Unfinished: see task-19-report.md
- Ease slope damping over 8 stations, so a cliff no longer jerks the line sideways and tilts the brink
- Guard the brink, chord tilt and centreline over seeds 1 to 24 and cliff edges 193 to 199
- Recapture the edge 199 brink pin and run the edge overhang test over 8 shape seeds
- Run the wall cut test over 8 seeds with a per-case cap and a pooled mean cap
- Check that every pond beyond the sliver is kept, and skip only the level check on its downstream chain
- Exempt only ponds on the sliver's downstream chain, so far pond loss and level changes fail again
- Add a 30-block mean cap over the nine wall feet beside the 35-block per-foot cap
- Read centreline columns for every land point, so a cliff between lattice nodes lowers the read even where the node gate stays shut
- Close the trim where the channel edge at the next midpoint or the bank is below it, so an angled cliff gains no extra overhang
- Test station phases and fractional edges, angled cliffs and uniform slope 1 directly
- Assert the gate position directly instead of only against a mirror
- Pin the brink for each on-lattice edge instead of a range
- Add Taubin relaxation of the resampled D8 line, with a 4-block shift limit and 4-block re-spacing
- Scale meander amplitude and wavelength by half-width and keep 40 percent of it on steep ground
- Use a smoothstep end envelope so short reaches keep their curve with exact endpoints
- Soften Viterbi offsets by half a node and pull back where the neighbouring node is blocked
- Move meander and Viterbi offsets along the relaxed line's normals so meander cannot tilt the valley read
- Hold meander to zero where a pond lies within its swing, so outlets stay on the shore
- Add steep-channel, reduced-meander, blocked-node and translation guard tests
- Revise fixture assumptions that required straight lines or one station phase
- ReachFitter reads ground with lowestCoveredGround, dropping nodes more than 2.5 blocks ahead only at a cliff edge
- Exact columns from a point to the midpoint of its next segment cap the trimmed read, so water never overhangs a cliff between lattice nodes
- T5 second case and cliffBetweenLatticeNodesKeepsWaterBelowTheGround cover the brink position and the centreline
- stepsBelowTheWaterfallMinimumKeepTheFullGroundRead pins the waterfall minimum gate
- cascades description separates cascade-start and waterfall-start steps; schema digest recaptured
- WaterInvariants.held holds a fed start only above MAX_START_LOWERING, as LinkBlend.fixed does
- Test that a lake outlet is not held along its lip across a window line, unlike a pond outlet
- Test tailouts across chunk borders with a diagonal and a jogged next step
- Share the chunk-border comparison between the plunge and tailout tests
- Parity test maps roles to palettes with a switch
- Parity test asserts some trials have open water under a fall
- Floor non-estuary pools at the lowest grade whose snapped head is above the sea
- Add WaterHeads.lowestAboveSea beside the snap rule it follows
- Restore the strict delta branch check on grouped settings
- Assert grouping moves no sea-level head upstream on the delta fixture
- Update the cascades schema description and recapture the schema digest
- Measure pools by arc on a gentler run
- Test close falls stay separate when the lower lands on the end level
- Add StepPools to group drops into level pools on cascading tiers
- Pass the seed through ReachGrader and record each point's floor
- Stop a waterfall absorbing the run-out at one waterfall's depth, so falls never merge
- Hold non-estuary points above sea level so no pool pulls the sea upstream of the estuary
- Protect pond outlet starts and every held point from grouping
- Test step pools, plunge reaches, tall-fall rollover and pond outlet zones
- Check the short-pit lock on ungrouped grades and bound grouped grades by one pool length
- Count visible drops in the gradeNeverRisesDownstream ratio
- Check the delta branch water on ungrouped grades and within one pool length when grouped
- Only the Bukkit bootstrap calls it, and modded jars bundle their natives
- It references the excluded SlimJar, which failed all 12 modded verifiers
- Remove a test import left unused by the noise pin
- Schema digest for the merged lanes
- Noise pin accepts the Windows and Mac rounded hashes
- Noise output is unchanged: the original raw-bit pin still passes on this line
- Bring back 5 commits a force push dropped from GitHub master (0aad88c30)
- Keep the thin Bukkit entry; port language sync into IrisRuntime
- Fetch guides through GitHubLanguageSource instead of the removed catalog
- Purity ratchet compares source paths with forward slashes
- Hydrology plan reads and saves share a striped file lock
- Offline region generator skips directory sync on Windows
- Noise seed pin hashes samples rounded to 9 decimal places
- Language guide test ignores line endings
- Language hotload test uses the VolmLib size limit
- Region snapshot tests skip without file keys
- Region snapshot test covers reads without file keys
- Open region replacement test skips on Windows
- Attach signal test links sigaction after the Windows check
- Offline publication test expects only file syncs on Windows
- Supply hydrology water to the native structure stages through IrisStructureWater on the Bukkit and modded policies
- Carry each native placement's allowWater on its start plan
- Judge native placements by the columns their assembled pieces cover in the stage instead of by the start chunk at plan time
- Apply the same start rule in the headless probe planner
- Move Iris structure footprints and carves onto the shared StructureWaterRules and remove StructureWaterFootprint and StructureCarveWater
- Add allowWater to the content-derived placement identity when set, so deduplicated native starts do not depend on list order
- Pass dry water to native terrain integrator calls in the adapter tests
- missingSurface: a sea-floor head under sea layers or sea decoration holds its cover or its own planned fluid, so a wrong fluid at a frozen estuary or inlet head fails again (R76).
- Column parity test mirrors the open-water-under-a-fall rule with a random 4-neighbour of its own head and role, guarding the actuator against drift from the mantle fall rule.
- An inlet mouth under a fall keeps open sea water, and one without a fall keeps its sea layers.
- bermOverCap still counts an over-cap wall beside a lake's outlet, which is never held.
- The plunge bowl ends at the next step's brink when that brink is nearer than the pool radius, so the pool rises back to the crest and the brink keeps 1-block water (R78).
- A brink distance field over the foot level, seeded at cells with a 4-neighbour at least 2 lower, sets each cell's span to the smaller of the radius and its foot-plus-brink distance; without a brink in reach the span is the radius, as before.
- The depth under the fall foot is unchanged; with no cell between the foot and the brink only the brink keeps its sill, and a foot that is itself a brink keeps the sill.
- Removes the 4 tick conversion cells at 146..148,329,-2826..-2828 and 489,329,-2182 where corner falls sat beside deep brink water.
- Add the allowWater structure placement field and recapture the schema digest
- Skip surface Iris structures whose piece footprint is more than 10% channel, pond, cascade or waterfall water
- Skip surface native placements whose start chunk is more than 10% of that water
- Fail closed on a provisional water answer off the server thread
- Keep BORE and FORCE_CARVE out of water columns from two blocks below the floor and out of the two-block bank up to the water surface
- Run structure pieces and stilts inside a MantleWriter object placement that applies the object water veto unless the placement allows water
- Let forced single pieces of allowWater structures enter water like an object's own forcePlace
- Apply the object water veto to floating-island object transactions
- Share the veto between the destination transaction, MantleWriter and floating transactions
- Reset the destination transaction's water flag when an object placement ends
- WaterInvariants.held mirrors LinkBlend.fixed after R72: a CASCADE whose 1-block drop leaves a held point stays held, and a fed start feeds that chain.
- Seed 4 on lane B's cup layout has a CHAINED pond outlet zone that steps 56 to 55 (shown 56 to 54, restyled CASCADE by Task 15) and continues held at 55 before cascading into the junction; the scan flagged that one step point as a tongue.
- PlannedSceneTest.outletZoneStepThatShowsAsTwoBlocksStaysHeld pins the styled zone step as held and the same step left unstyled as a tongue.
- Merge lane A Task 15 (6aafec196, 90205dc5f): plunge pools below falls, junction seam and tongue fixes, outlet zone step hold.
- No textual conflicts; ConfluenceIncisionTest keeps the integration MAX_WALL_CUT of 29 beside lane A's shared valley scene and tongue test.
- Pinned constants unchanged: schema digest, hydrology fingerprint and golden hashes pass as merged.
- missingSurface lets mouth columns take the biome sea layers like inlet columns, as the terrain stage paints them
- missingSurface accepts the biome's own decoration at the head of mouth and inlet columns, which are decorated like the sea they join
- missingSurface expects each column's effective fluid, so seam columns expect their seam
- risingWaterSegments compares reach heads with the pond's snapped head instead of its raw level
- bermOverCap spares the containment wall of pond outlet water held at its pond's head, the accepted perched flume
- Estuary and inlet columns that a higher neighbouring water column falls into skip the sea layers, so falling water lands in open sea water instead of spreading over sea ice
- Fall check compares the unclamped water head with the 4-neighbour wet heads, the rule the mantle uses to place falls
- IrisTerrainNormalActuatorHydrologyTest.aFallIntoAFrozenMouthLandsInOpenWater pins the open plunge and keeps ice beside level water and dry banks
- Sapling growth, Bukkit and modded object paste and Bukkit structure place no longer catch ProvisionalAnswerException, since explicit-Y placement never reaches the provisional guard
- The three retry messages are removed from the message catalogs and every bundled language
- Bukkit structure place records its changes for /iris object undo after a successful placement, as the modded command does
- The sapling test that reached the catch through a throwing tree is removed
- IrisObjectPlacement.entersWater is true for underwater, onwater and an object's own forcePlace, not for forced structure pieces
- Object placements pass entersWater to the destination transaction, so onwater and self-forced objects keep solid blocks in channel and pond water
- The water surface support gate reads the same predicate
- The mutation log and source plans carry the flag as entersWater
- Tests cover a one-block onwater raft and a self-forced block kept on a river, a forced structure piece still vetoed, and replay
- LinkBlend holds a cross-window feeder point that steps one block down as a CASCADE out of a held point, so the restyled last point of an outlet zone keeps its grade as in-window grading does
- Plunge distance fields stop at the bowl radius instead of LIMIT, with identical beds
- Test: cross-window settling keeps a one-block step at the end of an outlet zone
- Bukkit structure place catches ProvisionalAnswerException around the piece loop
- Pieces already written are recorded for /iris object undo, as the modded command does
- The player gets a retry message with the placement position
- The new message is translated in every bundled language
- Automatic placement is a context flag set by the IrisObject x,z overloads instead of any negative Y
- An explicit world Y below zero places at that Y and skips the provisional guard, so saplings, pastes and structure pieces in -64 worlds land where asked
- Mantle surface, procedural, floating and single-piece structure placements call the automatic overloads
- A structure piece at world Y -1 places at its own height instead of a sampled one
- Tests cover explicit negative Y, the provisional guard on automatic placements only, and saplings growing below zero
- The sapling provisional test throws from the tree placement since explicit growth never reaches the guard
- RiffleProfile carves a plunge pool at the foot of every head step of 6 or more blocks in channel water: depth round(0.5 x drop x (0.85 + 0.15 x variation)) clamped to 2..8, radius clamp(0.75 x drop, 3, 12), one distance field per foot and top head pair that spreads only through the foot level, LIMIT kept at 160
- Riffle crests at least 5 blocks above a cell's sill no longer raise its bed, so the foot of a large fall stays deep while the brink keeps its head-1 sill
- Plunge pools never seed in or carve pond, lake, sea inlet or mouth columns
- The riffle raise below a step between two different channel reaches leaves the lower channel's bed alone (spec 11 design D); fields are keyed by crest level, feature and flowing role
- RiffleProfile samples head, feature and role per column through a Water sampler; WaterRole.flowing names the channel, cascade and waterfall roles
- RasterComposer styles a channel column below another channel reach's water 2 or more blocks higher as CASCADE, or WATERFALL from the higher reach's waterfallMinimumDrop
- ReachShaper.styles takes the sea level and styles a one-block drop out of an outlet zone or held lip as CASCADE when the head snap shows it as a two-block step; LinkBlend restyles with the same rule
- LinkBlend.settleInto holds a cross-window feeder's start only for a pond lip, a pond outlet or a fed start more than one block above the junction, the in-window p0cap1 rule
- Tests: plunge pool, chunk-border and standing-water RiffleProfile cases, receiving bed below a joining cascade, styled lower-channel edges, falls into ponds and mouths keep their floors, cross-window fed start, held-lip step styles, and no confluence tongues on the cached 2x2 openFractal and sloping valley scenes
- IrisObjectPlacement.toPlacement copies forcedByStructure, so slope-turned structure pieces keep the river and pond exclusion
- Tests cover the copied marker and a slope-turned forced piece over a river
- Wet hydrology columns reject solid object blocks between the bed and the surface unless the object is underwater
- The column role, head and bed come from the water role, water head and height streams
- Object placements tell the destination transaction whether they are underwater
- The mutation log and source plans carry the underwater flag so destination replay applies the same rule
- Tests cover canopies over channels and ponds, underwater exemptions, replay, piers and sea inlet slots
- Single-piece structures stay forced but keep the river and pond exclusion
- Water-flagged objects skip footprints on dams, cascades, waterfalls or water at another head
- The provisional guard runs before any bore and throws an engine failure
- Saplings stay when a tree override is rejected or the terrain is still being planned
- Object paste reports a retry when the terrain is still being planned
- Tests cover structures over rivers, flat water, lava, bore ordering, explicit Y and saplings
- Merge lane B (sea surface, sea inlets, cave pools, wetness, persisted codes, scheduling knobs) onto lane A
- PackHydrologyValidatorTest keeps lane A's loadHydrology helper and lane B's validation tests
- Recapture HydrologySettingsTest.DEFAULT_FINGERPRINT and SchemaBuilderIdentityTest.EXPECTED_SCHEMA_DIGEST for the combined settings and schema
- Hold a fed feeder's start only when it stands more than 1 block above its junction, so 1-block riffle starts join the receiving water
- Keep a fed start in the tongue invariant's pool zone as a held point that must cascade into its junction
- Drop the held-lip riffle tolerance and assert no tongues on the seeds again
- Stop the junction-level and led-in pool walks only at a styled fall from a held start or from more than 5 blocks beside the bank
- Cover 1-block fed starts in grader unit tests and riffling held starts in the scene invariant tests
- Hydrology support gate applies only to land placements; underwater, onwater and forcePlace skip it
- Underwater and onwater anchors use the hydrology bed and head through the existing sea checks
- Automatic placements throw when any height or water answer before the block pass was provisional
- PlacementModuleSurfaceSupportTest covers ponds, rivers, forcePlace, dry columns and provisional water
- Drop the test that kept forcePlace out of river water
- Treat an inland hollow as open when its basin box would pass 2^20 cells, decided from the whole hollow
- Mark a classified hollow's cells inside the window as seen so its other pieces are not classified again
- Test a long diagonal trench classified open from two windows without sampling its basin box
- Fix a feeder's start in confluence grading when other reaches feed it, matching cross-window settling
- Pool feeder points outside every receiving channel only when they sit at most 5 blocks above the junction level
- Keep larger steps beside the receiving bank as a styled cascade or waterfall, in-window and across window lines
- Add valley trench, wall tributary and window copy regression tests plus grader unit tests
- Move the junction level, seam fall and led-in pool tests to the bank limit and fixed fed starts
- Mirror the fixed fed start and bank limit in the tongue invariant and classify held outlet lip riffles
- Policy fluid describes the per-stretch rule keyed on the upstream end, cave pools and the seam limit
- Policy class description covers region inheritance, whole-object wetness and cave-pool fluid order
- Wetness descriptions state that the bounded wetness also sets pond and lake drawdown
- Cave pool radius describes the square box around the site column
- Lake-borrowed pond fields name lakes: freeboard, climateDrawdown, materials, shore roundness, natural minDepth
- Lakes and ponds class descriptions list the pond settings lakes share
- Structure FLATTEN and SOURCE cuts beneath water or lava keep that fluid
- Studio Rivers view lists the water it draws instead of grottos
- Recapture the schema digest
- prefetchRings and persist leave the hydrology settings fingerprint, since they only choose which windows are prepared ahead and whether plans are saved
- Compile checks drainage.fillEpsilon as the compiled float, rejecting values that round to 0 or overflow to infinity
- DEFAULT_FINGERPRINT recaptured
- Warn in pack validate when a hydrologyPolicy.shoreBiomes list has no shoreBiomeWidth above 0 applying to it, naming the dimension, region or biome that lists it
- Resolve the shore band through IrisHydrologyPolicy.shoreBand for both runtime placement and reachability
- Walk region biome lineages in ShoreBiomeLineages so reachable biomes include only shore biomes a width places
- Make HydrologyShoreTargets.placesAny use the placed shore biomes, so the locator ignores lists without a width
- Take the dimension in IrisRegion.getAllBiomeIds and getAllBiomes and gate their shore biomes on hydrology
- Drop region biome additions the package compilers already get from the dimension's reachable biomes
- Seed unset region colours from the natural biome ids
- State in the shoreBiomes description that a width is required, and recapture the schema digest
- InlandHollows classifies below-sea land from the shared height lattice, following each hollow past the planning area, so every window that sees a hollow treats it the same way
- A hollow is inland only when it is ringed by land, touches no ocean and stays under 16384 cells; anything else, or a hollow held by a region lake, is left open
- The basin draining into a hollow is flooded in a box set by the hollow itself, not by the planning area
- Burned trunks are never dragged to sea level through ground more than deformation.maxFill above the sea; the trunk link is cut there and the trunk restarts at its own height
- BasinExtractor loses the window-local inland and draining scans
- Tests: hollow cut by a grid edge, lowland open to the sea, hollow held by a lake, trunk floor on high ground, and a hollow on a window line planned alike by both neighbouring windows
- Compile rejects prefetchRings outside 0..4, fillEpsilon not above 0 and seeded cup density outside 0..64
- Compile rejects negative tier widthFactor and depthRatio, waterfallMinimumDrop below 2 and shoreDepth below 1
- Compile rejects negative maxFill, lakes.maxArea above 2048 squared and seaInlets.spacing below 1
- Compile rejects enabled cave pools whose freeboard max reaches maxDepth or whose maxArea exceeds 961
- Lake and cave pool area schema maxima match the compiled bounds; schema digest recaptured
- Engine start checks dimension, region and biome policy fluids whether or not cave pools are enabled
- Pack validation warns on written tiers without halfWidth or bankBand and on useMantle false or RIVER_HYDROLOGY disabled
- Trunks are cut where they cross the natural basin draining into an inland hollow, so the major restarts beyond the rim instead of descending through it at sea level
- Lowland channels never climb more than 2 blocks above the lowest ground they crossed or the sea, in a new LowlandChannels helper
- Inland hollow ponds skip dams
- Hollow planner tests assert no reach is held at the sea under high ground and the valley past the rim matches the hollow-free valley
- Pondless inland hollows end streams at their edge
- One shared SeaCells test helper replaces the two copies
- Carry each column's bounded zone wetness and whether climate zones apply to it as wetness and climateZoned sample channels, copied by HeightLattice
- Draw pond and lake surfaces down by climateDrawdown times one minus the bounded zone wetness at the floor inside climate zones, and by one minus rainfall where the zones are off or climateZones is false
- Test the drawdown in wet, dry and transition zones and outside them, and that two windows give a pond the same level
- Test that a policy wetness min keeps a dry-zone pond from drawing down, from the terrain source through the planner
- Describe the rainfall policy as lowering ponds only where the climate zones do not apply
- Recapture the schema digest
- Reject a policy rainfall or pondDensity outside 0..16 when a column resolves it, naming the biome and region
- Report a policy rainfall or pondDensity outside 0..16 at every scope in pack validation
- Share the 0..16 bound between the schema, the terrain source and the validator through IrisHydrologyPolicy.MAX_MULTIPLIER
- Size the window cup grid from a double product of seeded density and peak pond density